Show simple item record

dc.contributor.authorErvik, Torunn Kringlen
dc.contributor.authorLeite, Mimmi
dc.contributor.authorWeinbruch, Stephan
dc.contributor.authorNordby, Karl-Christian
dc.contributor.authorEllingsen, Dag
dc.contributor.authorUlvestad, Bente
dc.contributor.authorDahl, Kari
dc.contributor.authorBerlinger, Balazs
dc.contributor.authorSkaugset, Nils Petter
dc.date.accessioned2024-08-20T06:39:17Z
dc.date.available2024-08-20T06:39:17Z
dc.date.created2024-06-17T08:58:43Z
dc.date.issued2024
dc.identifier.citationAnnals of Work Exposures and Health. 2024, 68 (7), 713-724.
dc.identifier.issn2398-7308
dc.identifier.urihttps://hdl.handle.net/11250/3147025
dc.description.abstractTunnel boring machines (TBMs) are used to excavate tunnels in a manner where the rock is constantly penetrated with rotating cutter heads. Fine particles of the rock minerals are thereby generated. Workers on and in the vicinity of the TBM are exposed to particulate matter (PM) consisting of bedrock minerals including α-quartz. Exposure to respirable α-quartz remains a concern because of the respiratory diseases associated with this exposure. The particle size distribution of PM and α-quartz is of special importance because of its influence on adverse health effects, monitoring and control strategies as well as accurate quantification of α-quartz concentrations. The major aim of our study was therefore to investigate the particle size distribution of airborne PM and α-quartz generated during tunnel excavation using TBMs in an area dominated by gneiss, a metamorphic type of rock. Sioutas cascade impactors were used to collect personal samples on 3 separate days. The impactor fractionates the dust in 5 size fractions, from 10 µm down to below 0.25 µm. The filters were weighted, and the α-quartz concentrations were quantified using X-ray diffraction (XRD) analysis and the NIOSH 7500 method on the 5 size fractions. Other minerals were determined using Rietveld refinement XRD analysis. The size and elemental composition of individual particles were investigated by scanning electron microscopy. The majority of PM mass was collected on the first 3 stages (aerodynamic diameter = 10 to 0.5 µm) of the Sioutas cascade impactor. No observable differences were found for the size distribution of the collected PM and α-quartz for the 3 sampling days nor the various work tasks. However, the α-quartz proportion varied for the 3 sampling days demonstrating a dependence on geology. The collected α-quartz consisted of more particles with sizes below 1 µm than the calibration material, which most likely affected the accuracy of the measured respirable α-quartz concentrations. This potential systematic error is important to keep in mind when analyzing α-quartz from occupational samples. Knowledge of the particle size distribution is also important for control measures, which should target particle sizes that efficiently capture the respirable α-quartz concentration.
dc.language.isoeng
dc.titleCharacterization of particle exposure during tunnel excavation by tunnel boring machines
dc.title.alternativeCharacterization of particle exposure during tunnel excavation by tunnel boring machines
dc.typePeer reviewed
dc.typeJournal article
dc.description.versionpublishedVersion
dc.source.pagenumber713-724
dc.source.volume68
dc.source.journalAnnals of Work Exposures and Health
dc.source.issue7
dc.identifier.doi10.1093/annweh/wxae041
dc.identifier.cristin2276546
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record