Show simple item record

dc.contributor.authorGaté, Laurent
dc.contributor.authorKnudsen, Kristina Bram
dc.contributor.authorSeidel, Carole
dc.contributor.authorBerthing, Trine
dc.contributor.authorChézeau, Laëtitia
dc.contributor.authorJacobsen, Nicklas Raun
dc.contributor.authorValentino, Sarah
dc.contributor.authorWallin, Håkan
dc.contributor.authorBau, Sébastien
dc.contributor.authorWolff, Henrik
dc.contributor.authorSébillaud, Sylvie
dc.contributor.authorLorcin, Mylène
dc.contributor.authorGrossmann, Stéphane
dc.contributor.authorViton, Stéphane
dc.contributor.authorNunge, Hervé
dc.contributor.authorDarne, Christian
dc.contributor.authorVogel, Ulla
dc.contributor.authorCosnier, Frédéric
dc.date.accessioned2024-08-21T11:22:39Z
dc.date.available2024-08-21T11:22:39Z
dc.date.created2019-05-13T09:10:24Z
dc.date.issued2019
dc.identifier.citationToxicology and Applied Pharmacology. 2019, 375 17-31.
dc.identifier.issn0041-008X
dc.identifier.urihttps://hdl.handle.net/11250/3147366
dc.description.abstractMulti-walled carbon nanotubes (MWCNTs), which vary in length, diameter, functionalization and specific surface area, are used in diverse industrial processes. Since these nanomaterials have a high aspect ratio and are biopersistant in the lung, there is a need for a rapid identification of their potential health hazard. We assessed in Sprague-Dawley rats the pulmonary toxicity of two pristine MWCNTs (the “long and thick” NM-401 and the “short and thin” NM-403) following either intratracheal instillation or 4-week inhalation in order to gain insights into the predictability and intercomparability of the two methods. The deposited doses following inhalation were lower than the instilled doses. Both types of carbon nanotube induced pulmonary neutrophil influx using both exposure methods. This influx correlated with deposited surface area across MWCNT types and means of exposure at two different time points, 1–3 days and 28–30 days post-exposure. Increased levels of DNA damage were observed across doses and time points for both exposure methods, but no dose-response relationship was observed. Intratracheal instillation of NM-401 induced fibrosis at the highest dose while lower lung deposited doses obtained by inhalation did not induce such lung pathology. No fibrosis was observed following NM-403 exposure. When the deposited dose was taken into account, sub-acute inhalation and a single instillation of NM-401 and NM-403 produced very similar inflammation and DNA damage responses. Our data suggest that the dose-dependent inflammatory responses observed after intratracheal instillation and inhalation of MWCNTs are similar and were predicted by the deposited surface area.
dc.description.abstractPulmonary toxicity of two different multi-walled carbon nanotubes in rat: Comparison between intratracheal instillation and inhalation exposure
dc.language.isoeng
dc.titlePulmonary toxicity of two different multi-walled carbon nanotubes in rat: Comparison between intratracheal instillation and inhalation exposure
dc.title.alternativePulmonary toxicity of two different multi-walled carbon nanotubes in rat: Comparison between intratracheal instillation and inhalation exposure
dc.typePeer reviewed
dc.typeJournal article
dc.description.versionpublishedVersion
dc.source.pagenumber17-31
dc.source.volume375
dc.source.journalToxicology and Applied Pharmacology
dc.identifier.doi10.1016/j.taap.2019.05.001
dc.identifier.cristin1697265
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record