Interlaboratory comparison of endotoxin contamination assessment of nanomaterials

Hannon, Gary; Heaton, Bethany J.; Plant-Hately, Alexander; David, Christopher; Liptrott, Neill J.; Egizabal, Ainhoa; Ayerdi-Izquierdo, Ana; Alvarez, Noelia; Ibarrola, Oihane; Celaya, Andres Arbona; Perez, Angel Del Pozo; Lazcanoiturburu, Nerea; Luzuriaga, Iris; Zegeye, Fikirte Debebe; Zienolddiny-Narui, Shan; Jacobs, An; Van Driessche, Alexandra; Nelissen, Inge; Abasolo, Ibane; Andrade, Fernanda; Ventosa, Nora; González-Mira, Elisabet; Carreño, Aida; Prina-Mello, Adriele
Peer reviewed, Journal article
Published version
Thumbnail
View/Open
d4nr02821j.pdf (717.8Kb)
URI
https://hdl.handle.net/11250/3166494
Date
2024
Metadata
Show full item record
Collections
  • Publikasjoner fra Cristin - STAMI [844]
  • Vitenskapelige artikler/ Scientific articles [734]
Original version
10.1039/d4nr02821j
Abstract
Endotoxin contamination is a significant hurdle to the translation of nanomaterials for biomedical applications. Multiple reports now describe that more than one-third of nanomaterials fail early pre-clinical assessment due to levels of endotoxin above regulatory requirements. Additionally, most immunological studies or in vivo studies testing nanomaterials in the literature lack inclusion of this assessment, which may lead to false-positive or false-negative results if high levels of the contaminant are present. The currently approved methods for endotoxin contamination assessment rely on enzymatic activity and wavelength absorbance as their endpoint, and many nanomaterials can interfere with such assays. For this reason, we devised an interlaboratory comparison of endotoxin contamination assessment for a range of nanomaterials to challenge the current international organization for standardization and pharmacopeia standards. Herein, we show that detected endotoxin levels could vary considerably between groups, and, in some instances, nanomaterials could both pass and fail regulatory endotoxin limits for medical devices depending on the group undertaking the assessment, all while passing all quality criteria standards. This work emphasises the requirement for multiple assays to fully assess the endotoxin levels in a nanomaterial and highlights the need for additional assays to be developed in this space.
Journal
Nanoscale

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit